5.19    Rising Mains

Rising mains shall meet the requirements for water supply pressure mains.  Rising mains in private property shall be located clear of building sites and the alignment protected by 'Easement in Gross'.  The test pressure shall be at least twice the maximum working pressure and the final test must be witnessed by Council. 

Only polyethylene pipe may be used for wastewater rising mains.

Air relief valves shall be fitted as necessary and/or as required by Council.